  • SM39PWB-SFLYC double flange remote transmission diaphragm pressure transmitter
  • SM39PWB-SFLYC double flange remote transmission diaphragm pressure transmitter

Double flange remote transmission diaphragm pressure transmitter

Deskripsi Produk

Apply

The membrane box of the double flange remote diaphragm pressure transmitter is used in the pressure sensor assembly to prevent the medium in the pipeline from directly entering the transmitter. The filling liquid such as silicon oil is used between it and the transmitter.

The SM39PWB-SFLYC double flange remote diaphragm pressure transmitter is used to measure the liquid level, density and pressure of liquid, gas or steam, and then convert it into 4 mA to 20 mADC HART current signal output. It can also communicate with HART handheld terminals for parameter setting, process monitoring, etc.

The measurement range of SM39PWB-SFLYC double flange remote diaphragm pressure transmitter (without migration) is 0-1 kPa ~ 2 MPa, and the rated pressure of remote flange is 1.6/4MPa, 6.4MPa 10MPa, 150 psi, 300 psi or 600 psi respectively.

operational principle

The SM39PWB-SFLYC double flange remote diaphragm pressure transmitter is composed of SM39PWB-CY series differential pressure transmitter and welded mounted capillary remote transmission flange. Its working principle is the same as that of CY series differential pressure transmitter (technical specifications of CY series differential pressure transmitter), but the pressure transmission path is slightly different: the pressure acting on the side of the remote flange, first through the diaphragm and filling liquid on the remote flange, then through the capillary, and finally to the corresponding positive and negative side of the measuring sensor.

Rasakan dunia Hubungkan dunia Inovasi SUNMOON

Input

Measurement parameters: differential pressure and liquid level measurement range

Lower limit: -100% URL (continuously adjustable)

Upper limit: to + 100% URL (continuously adjustable)

range

Table 1 Compartable of relationship between range code and range

Quota codeminimum rangemetre fullscaleRated pressure (max.)
B1kPa6kPa  Far pass flange rated pressure
C4kPa40kPa
D25kPa250kPa
E200kPa2MPa

Table 2 Control table of the relationship between distant flange and minimum range

 Flange liquid level nominal diameterminimum range
Single remote transmissionBilateral distant transmission
 Flat typeDN50/2〞10kPa10kPa
DN80/3〞6kPa1kPa
 DN4〞6kPa1kPa
 plug-inDN50/2〞16kPa16kPa
DN80/3〞6kPa1kPa
DN4〞6kPa1kPa

The minimum range of the remote transmitter shall be the larger value of the minimum range in Tables 1 and 2. The adjusted range shall not be less than the minimum range. The maximum range of the remote transmitter shall be the minimum value of the maximum range and the rated pressure of the liquid level flange.

Output output signal

Second-line system, 4 mA ~ 20 mADC HART output, digital communication, HART protocol loaded on 4 mA ~ 20 mADC signal. Output signal limit: I mi n = 3.9 mA and Imax = 2 0 .5 mA

response time

The damping constant of the amplifier component is 0.1s; the time constant of the sensor and remote flange is 0.2s~6s, depending on the range of the sensor, the length of the capillary, and the viscosity of the filling fluid. The additional adjustable time constant is: 0.1s~60s.

general conditions

  • Installation conditions

The transmitter body can be directly fixed in any position. The best state is to make the process flange axis in the vertical state, the position deviation will produce a correctable zero offset. The electronic watch case can rotate up to 360°, and the positioning screws can hold it in any position. The remote transmission flange is connected to the supporting flange conforming to ANSI / DIN standard, which shall be equipped with soft gasket and fixed bolts and nuts (optional mounting bolts and nuts). For bilateral flanges, capillary parts and remote flanges shall only be installed in the same ambient temperature. The minimum bending radius of the capillary is 75mm, and winding is strictly prohibited!

3.2 ambient condition

ambient temperature

Minimum: depending on the filling fluid

The highest: 85℃

-20℃ ~65℃ with liquid crystal display and fluorine rubber sealing ring

Minimum: Depending on the filling fluid, maximum: 85℃

relative humidity: 0%~100%

shock resistance Acceleration: 50g

Duration: 11ms

Anti-vibration From 2g to 500Hz

Electromagnetic compatibility (EMC)

See Table 4 on the next page

3.3 Limit-temperature limit of the process medium

Temperature of the medium: -30℃ ~400℃

Table 3 Fill fluid, working temperature and minimum working static pressure relationship table

 Fillersilicone oil(S)High temperature silicone oil(H)Ultra-high temperature silicone oil(U)plant oil(V)
Density (25℃)960kg/m³980kg/m³1020kg/m³937kg/m³
operating temperature range-30℃~200℃-10℃~350℃-10℃~400℃0℃~250℃
temperatureWorking static pressure range (kPa pressure)
20℃>10>10>10>25
100℃>25>25>25>50
150℃>50>50>50>75
200℃>75>75>75>100
250℃ >100>100>100
350℃ >100>100 
400℃  >100 

Note: beyond the above working temperature and static pressure relationship range, the requirements can be met by special design. Transmitter body pressure limit

From 3.5kPa absolute pressure to rated pressure, the protection pressure can be 1.5 times the rated pressure and added to both sides of the transmitter. Far pass flange rated pressure

ANSI standard: 150 psi to 600 psi

DIN Standard: PN1.6MPa~PN 10MPa

One-way overload limit

The low pressure side is the rated pressure of the transmitter body, and the high pressure side is the rated pressure of the remote transmission flange, which may be a modifiable zero drift.

weight

The single remote transmission is 50 / 2 ″ DN about 7~10kg, DN 80 / 3 ″ about 8~11kg, and DN 4 ″ about 9~12kg;

The bilateral remote transmission is DN 50 / 2 ″ about 10~16.5kg, DN 80 / 3 ″ about 12~18kg, and DN 4 ″ about 14~21kg.

  • Power supply and load condition power supply voltage is 24V

R (Us-12 V) / I ma x kΩ of which I ma x = 2 3  mA

Maximum power supply voltage: 42VDC

Minimum power supply voltage: 12VDC, 15VDC (backlit liquid crystal display) digital communication load range: 250 Ω ~600 Ω

material quality

Measurement membrane box: stainless steel 316L

Membrane: stainless steel 316L, Hab C, tantalum process flange: stainless steel 304

Filling liquid: silicone oil, high temperature silicone oil, ultra-high temperature silicone oil, vegetable oil

Seal ring: nitrile rubber (NBR), fluorine rubber (FKM), polytetrafluoroethylene (PT F E) transmitter shell: aluminum alloy material, exterior spray epoxy resin

Housing sealing ring: nitrile rubber (NBR)

Nameplate:, stainless steel 304

Electrical connection

M20 X 1. 5 Cable seal buckle, wiring terminal is suitable for 0.5 m m 2~ 2.5 m m 2 wire.procedure linkage

1 / 4 NPT internal thread on the low pressure side of the transmitter.

The level flange on the high pressure side of the transmitter meets ANSI or DIN standards. Can be installed directly, according to the overall size. Housing protection level: IP67

Table 4 Table table for electromagnetic compatibility

order numbertest itembasic criteriontest conditionPerformance level
1Radiation interference (enclosure)GB / T 9254-2008 Table 530MHz~1000MHzqualified
 2conducted interference(DC power supply port) GB / T 9254-2008 Table 1 0.15MHz~30MHz qualified
 3Electrostatic discharge (ESD) immunity GB/T 17626.2-20064kV (contact point)8kV (air) B
 4 RF electromagnetic field immunity GB/T 17626.3-200610V/m (80MHz~1GHz) A
5Power-frequency magnetic field immunityGB/T17626.8-200630A/mA
 6Electric fast transient pulse populationnoise immunity GB/T 17626.4-2008 2kV(5/50ns,5kHz) B
 7 Wave surge resistance GB/T 17626.5-20081kV (between the lines)2kV (between lines and ground)(1.2us/50us) B
 8Conduction of the RF field inductionInterference with perturbation GB/T 17626.6-2008 3V(150kHz~80MHz) A

Note 1: A Performance grade description: normal within the limit of technical specification.

Note 2: B Performance rating description: During the test, the function or performance is temporarily reduced or lost, but it can be restored by itself, and the actual health, storage and data do not change.

outline dimension

unit (mm)

1 Figure of basic bilateral differential pressure far transmission seal device

Figure 2 Figure of basic unilateral differential pressure far transmission seal device

Note 1: The unilateral basic differential pressure far transmission seal device can be installed on the high pressure side of the transmitter body or on the low pressure side of the transmitter;

Note 2: The installation mode of the transmitter body for the unilateral or bilateral basic differential pressure remote transmission sealing device is the same as the SM39PWB-CY series differential pressure transmitter.

Table 5 Table of remote transmission flange structure dimensions

 nominal diameter rated pressure ΦD ΦK Φ d1, insert set Φ d2, Flat Eq Φd3 t bRequires the bolt
countmeasure screw thread
DN50PN 1.6/4MPa16512548.3571023+0.5204M16
(Seal face type DIN2526E)PN 6.4MPa18013548.3571023+0.5264M20
(Flange DIN2501)PN 10MPa19514548.3571023+0.5284M20
DN80PN 1.6/4MPa20016076751383+0.5248M16
(Seal face type DIN2526E)PN 6.4MPa21517076751383+0.5288M20
(Flange DIN2501)PN 10MPa23018076751383+0.5328M24
 DN 2″(ANSI B 16.5 RF) 150psi 300psi 600psi 152.4165.1165.1 120.6127.0127.0 48.348.348.3 575757 92.192.192.13+0.53+0.56.3517.420.631.75 488 M18 M18 M18
 DN 3″(ANSI B 16.5 RF) 150psi 300psi 600psi 190.5209.5209.5 152.4168.3168.3 767676 757575 1271271273+0.53+0.56.3522.227.038.05 488 M16 M20 M20
DN 4″150psi22919189891573+0.5308M18
(ANSI B 16.5 RF)300psi25520089891573+0.5328M18

Note: Users can choose the mounting bolts and nuts.

Figure. 3 Diagram of bilateral thread mounting differential pressure remote transmission seal device

Figure 4 Unilateral thread-mounted differential pressure remote transmission seal device

Note: The single thread-mounted differential pressure seal device can be installed on the high pressure side of the transmitter body or the low pressure side of the transmitter; the transmitter body of the single-sided thread-mounted differential pressure seal device is the SM39PWB-CY series differential pressure transmitter.

  • Electrical connection

Figure 5. Electrical connection diagram

Note: The shortcut interface function is equivalent to the signal terminal.

  • Description of process connection of single remote / remote flange end

Hubungi Kami !

Harap aktifkan JavaScript di browser Anda untuk melengkapi formulir ini.

mitra

mitra
Tinggalkan pesan!
Selamat datang untuk meninggalkan pesan dan memperoleh penawaran produk. Kami akan membalas Anda dalam waktu 24 jam.
Harap aktifkan JavaScript di browser Anda untuk melengkapi formulir ini.
SILAHKAN HUBUNGI KAMI
Harap aktifkan JavaScript di browser Anda untuk melengkapi formulir ini.