LARProdutosTransmissor de temperatura de pressãoDifferential pressure transmitterDifferential pressure sensor
  • Transmissor de pressão diferencial SM39PWB-CY
  • Transmissor de pressão diferencial SM39PWB-CY

Differential pressure sensor

Descrição do produto

The SM39PWB-CY differential pressure transmitter is used to measure the liquid level, density, pressure, and flow rate of liquid, gas or steam, and then convert it into 4 mA to 20 mADC HART current signal output. It can also communicate with HART handheld terminal for parameter setting, process monitoring, etc.

Perceba o mundo Conecte o mundo Inove o SUNMOON

Differential pressure sensor standard specifications

(Adjust range on standard zero, stainless steel 316L diaphragm, filling liquid is silicone oil)

Differential pressure sensor performance requirement

Reference accuracy of scalrange (including linearity, regression, and repeatability from zero):

± 0.075% If TD> 10 (TD= maximum range / adjusted range) is: ± (0.0075 TD)%

The square root output accuracy is 1.5 times of the above linear reference accuracy. Environmental temperature impact

Over the scope of influence

±0.075%×Span

Static pressure effect

Quota codeinfluence quantity
UM±(0.5%Span)/4MPa
B±(0.3%Span)/16MPa
F /G /H/I/J±(0.1%Span)/16MPa

Overpressure effect

Quota codeinfluence quantity
UM±0.5%×Span/4MPa
B /C/D/E±0.2%×Span/16MPa
F /G /H/I/J±0.1%×Span/16MPa

long term stability

Quota codeinfluence quantity
UM±0.5%×Span/1year
B±0.2%×Span/1year
F /G /H/I/J±0.1%×Span/1year

 Power impact

± 0.001% / 10V (12 to 42 VDC), negligible.

Differential pressure sensor functional specification

Range and range

Range / rangekPa
 UMrange0~1
scope-3000~3000
 Brange1~100
scope-16000~16000
 Crange100~500
scope-16000~16000
 Erange500~3000
scope-16000~16000
 Erange3000~4000
scope-16000~16000
 Frange4000~10000
scope-16000~16000
 Grange1~100
scope16000~30000
 Erange100~500
scope16000~30000
 EUrange500~3000
scope16000~30000
 Eurange3000~4000
scope16000~30000

 Quantity limit

In the upper and lower limits of the range, can be adjusted.

It is recommended to choose a range code as low as possible to optimize the performance characteristics. Zero point setting

The zero and range can be adjusted to any value within the measurement range in the table, as long as the calibration range minimum range

 Installation location impact

The change of the installation position in the parallel direction of the membrane will not cause zero drift effect. If the installation position and the one direction of the membrane change more than 90°, the zero position in the range of <0.4 kPa will occur, which can be adjusted by adjustment. There is no quantitative impact.

saída

Second-line system, 4 mA ~ 20 mADC, optional HART output digital communication, optional linear or square root output. Output signal limit: Imin=3.9mA,Imax=20.5mA

response time

The damping constant of the amplifier component is 0.1s; the sensor time constant is 0.1s~1.6s, depending on the range and the range ratio. The additional adjustable time constant is: 0.1s~60s. The effect on the nonlinear output (e. g., the square root function) depends on that function and can be calculated accordingly.

preheating time

<15s

ambient temperature

-40℃~85℃

-20℃ ~65℃ with liquid crystal display and fluorine rubber sealing ring

-50℃ ~85℃; with liquid crystal display: -40℃ ~85℃ working pressure

The rated working pressure is divided into: 16MPa, 25MPa and 40MPa three gear static pressure limit

From 3.5kPa absolute pressure to rated pressure, the protection pressure can be 1.5 times the rated pressure and added to both sides of the transmitter. One-directional overload limit:

Electromagnetic compatibility (EMC)

See EMcompatibility schedule on the following page

Differential pressure sensor install

Power supply and load conditions

The power supply voltage is 24V, R (Us-12V) / Ima xkΩ among Ima x=23 m A

Maximum power supply voltage: 42VDC

Minimum power supply voltage: 12VDC, 15VDC (backlit liquid crystal display) digital communication load range: 250 Ω ~600 Ω

Conexão elétrica

 M201.5 cable seal buckle, the wiring terminal is suitable for 0.5m m2~2.5m m2The wire.procedure linkage

The two sides of the process connection flange have NPT 1 / 4 and UNF 7 / 16 ″ internal threads.

Differential pressure sensor Physical specifications

material quality

Measurement membrane box: stainless steel 316L

Membrane: stainless steel 316L, Harbin alloy C process flange: stainless steel 304

Nuts and bolts: stainless steel (A4) filling fluid: silicone oil

Seal ring:, nitrile rubber (NBR), fluorine rubber (FKM), polytetrafluoroethylene (PT F E) transmitter shell: aluminum alloy material, exterior spray epoxy resin

Housing sealing ring: Nitrile rubber (NBR) nameplate:, Stainless steel 304

weight: 3.3kg (without: LCD display, mounting bracket, process connection)

Housing protection class IP67

The EMC schedule

order numbertest itembasic criteriontest conditionPerformance level
1Radiation interference (enclosure)GB / T 9254-2008 Table 530MHz~1000MHzqualified
 2conducted interference(DC power supply port) GB / T 9254-2008 Table 1 0.15MHz~30MHz qualified
 3 Electrostatic discharge (ESD) immunity GB/T 17626.2-20064kV (contact point)8kV (air) B
 4 RF electromagnetic field immunity GB/T 17626.3-200610V/m(80MHz~1GHz) UM
5Power-frequency magnetic field immunityGB/T 17626.8-200630A/mUM
6Electric fast transient pulse group immunityGB/T 17626.4-20082kV(5/50ns,5kHz) B

 Note 1: A Performance grade description: normal within the limit of technical specification.

Note 2: B Performance rating description: During the test, the function or performance is temporarily reduced or lost, but it can be restored by itself, and the actual health, storage and data do not change.

Outline dimension

Entre em contato conosco!

Ative o JavaScript no seu navegador para preencher este formulário.

parceiro

parceiro
Deixe um recado!
Fique à vontade para nos deixar uma mensagem e obter orçamentos de produtos. Responderemos em até 24 horas.
Ative o JavaScript no seu navegador para preencher este formulário.
POR FAVOR CONTATE-NOS
Ative o JavaScript no seu navegador para preencher este formulário.