LARProdutosTransmissor de temperatura de pressãoDifferential pressure transmitterSingle-flange differential pressure transmitter
  • SM39PWB-DFL single-flange differential pressure transmitter
  • SM39PWB-DFL single-flange differential pressure transmitter

Single-flange differential pressure transmitter

Descrição do produto

1 Apply

The membrane box of the remote transmission transmitter is a pressure sensor assembly used to prevent the medium in the pipeline from directly entering the transmitter, and the filling liquid such as silicone oil is used to transfer the pressure between the transmitter and the transmitter.

The SM39PWB-DFLYC series surface pressure / absolute pressure far transmission transmitter is used to measure the liquid level, density, pressure of liquid, gas or steam, and then convert it into 4 mA to 20 mADC HART current signal output.

It can also communicate with HART handheld terminals for parameter setting, process monitoring, etc.

The measurement range of SM39PWB-DFLYC series (without migration) is 0-6 kPa ~ 25 MPa, and the rated pressure of remote flange is 1. 6 / 4M P a, 6. 4 MPa 10MPa, 150 psi, 300 psi or 600 psi, respectively.

2 Working principle and structure

SM39PWB-DFLYC series gauge pressure / voltage remote transmission transmitter structure consists of SM39PWB-DFLYC series gauge pressure / voltage transmitter and welded mounted capillary remote transmission flange. The working principle is the same as that of the SM39PWB-DFLYC series pressure / pressure transmitter, but the pressure transfer path is slightly different: the pressure acting on the side of the remote flange, first through the diaphragm and filling fluid on the remote flange, then through the capillary, and finally to the measuring end of the measuring sensor.

Perceba o mundo Conecte o mundo Inove o SUNMOON

EUnput

Measurement range of differential pressure and liquid level

Lower limit: -100% URL from (continuously adjustable) Upper limit: to + 100% URL (continuously adjustable) range

Table 1 Compartable of relationship between range code and range

Quota codeminimum rangemetre fullscaleRated pressure (max.)
B1kPa6kPa  Rated pressure of a single flange
C4kPa40kPa
E25kPa250kPa
E200kPa2MPa

Table 2 Control table of the relationship between single flange and minimum range

Single flangenominal diameterminimum range
 Flat typeDN 50/2″10kPa
DN 80/3″1kPa
DN 4″1kPa
 plug-inDN 50/2″16kPa
DN 80/3″1kPa
DN 4″1kPa

The minimum range of the differential pressure level transmitter shall be the larger value of the minimum range in Table 1 and Table 2. The adjusted range shall not be less than the minimum range. The maximum range of the liquid level transmitter shall be the minimum value of the maximum range of the transmitter body and the single flange rated pressure.

saída

output signal

Second-line system, 4 mA ~ 20 mADC HART output, digital communication, HART protocol loaded on the 4 mA ~ 20 m ADC signal.

Output signal limit: I mi n = 3.9 mA and Imax = 2 0 .5 mA

response time

The damping constant of the amplifier component is 0.1s; the sensor and single-flange time constant is 0.2s~2s, depending on the range and range ratio. The additional adjustable time constant is: 0.1s~60s. The added adjustable time constant is: 0.1s~60s.

general conditions

4.1 Installation conditions

A single flange transmitter can be directly fixed in any position. The best state is to make the process flange axis in the vertical state, and the position deviation will produce a correctable zero offset. The electronic watch case can rotate up to 360°, and the positioning screws can hold it in any position.

4.2 ambient condition

ambient temperature

Minimum: Depending on the filling fluid, maximum: 85℃

Storage temperature / transport temperature at-20℃ ~65℃

Minimum: Depending on the filling fluid, maximum: 85℃

humidade relativa

0%~100%

shock resistance

Acceleration: 50g

Duration: 11ms for vibration resistance

2g to 500Hz electromagnetic compatibility (EMC)

See Table 3 on the next page

4.3 Process medium limit

Limit of medium temperature: -30℃ ~180℃

The pressure limit of the transmitter body is from 3.5kPa absolute pressure to rated pressure, the protection pressure can be greater than 1.5 times the rated pressure, and added to both sides of the transmitter.

Single-flange-rated pressure

ANSI standard: 150 psi ~ 600 psi DIN Standard: PN1.6MPa~PN 10MPa

One-way overload limit

The low pressure side is the rated pressure of the transmitter body, and the high pressure side is the single flange rated pressure, which may appear modifiable zero drift.weight

DN 50 / 2 ″ about 7~10kg; DN 80 / 3 ″ about 8~11kg and DN 4 ″ about 9~12kg. Explosion proof performance

NEPSI Isolation permit: Ex dⅡC T6 NEPSI License: Ex iaⅡC T4 allowed temperature: -40℃ ~65℃

4.4 Power supply and load conditions

The power supply voltage is 24V R (Us-12V) / I maxkΩ where Imax = 23 mA

Maximum power supply voltage: 42VDC

Minimum power supply voltage: 12VDC, 15VDC (backlit LCD display)

Range of digital communication load: 230 Ω ~600 Ω material

Measurement membrane box: stainless steel 316L

Membrane:, stainless steel 316L, Hab C, tantalum, FEP, PFA, PTFE coating process flange: stainless steel 304

Filling liquid: silicone oil, vegetable oil

Seal ring: nitrile rubber (NBR), fluorine rubber (FKM), polytetrafluoroethylene (PTFE)

Transmitter housing: aluminum alloy material, exterior spray epoxy resin shell sealing ring: nitrile rubber (NBR)

Nameplate:, stainless steel 304 electrical connection

M201.5 cable sealing buckle, the wiring terminal is suitable for 0.5 m m 2~ 2. 5 m m 2 wire.

procedure linkage

UNF 7 / 16 ″ inner thread on the transmitter LV side. The single flange on the high voltage side of the transmitter meets the ANSI standard or the DIN standard. Can be installed directly, and refer to the dimensional drawing.

Housing protection class IP67

Table 3 Table table for electromagnetic compatibility

order numbertest itembasic criteriontest conditionPerformance level
1Radiation interference (enclosure)GB / T 9254-2008 Table 530MHz~1000MHzqualified
 2conducted interference(DC power supply port) GB / T 9254-2008 Table 1 0.15MHz~30MHz qualified
 3Electrostatic discharge (ESD) immunity GB/T 17626.2-20064kV (contact point)8kV (air) B
 4 RF electromagnetic field immunity GB/T 17626.3-200610V/m (80MHz~1GHz) UM
5Power-frequency magnetic field immunityGB/T 17626.8-200630A/mUM
 6Electric fast transient pulse populationnoise immunity GB/T 17626.4-2008 2kV(5/50ns,5kHz) B
 7 Wave surge resistance GB/T 17626.5-20081kV (between the lines)2kV (between lines and ground)(1.2us/50us) B
 8Conduction of the RF field inductionInterference with perturbation GB/T 17626.6-2008 3V(150kHz~80MHz) UM

Note 1: A Performance grade description: normal within the limit of technical specification.

Note 2: B Performance rating description: During the test, the function or performance is temporarily reduced or lost, but it can be restored by itself, and the actual health, storage and data do not change.

outline dimension

nominal diameter rated pressure ΦD ΦKΦ d1, insert setΦ d2, Flat Eq Φd3 para bRequires the bolt
quantityscrew thread
DN50PN 1.6/4MPa16512548.3571023+0.5204M16
(Seal face type DIN2526E)PN 6.4MPa18013548.3571023+0.5264M20
(Flange DIN2501)PN 10MPa19514548.3571023+0.5284M20
DN80PN 1.6/4MPa20016076751383+0.5248M16
(Seal face type DIN2526E)PN 6.4MPa21517076751383+0.5288M20
(Flange DIN2501)PN 10MPa23018076751383+0.5328M24
 DN 2″(ANSI B 16.5 RF) 150psi 300psi 600psi 152.4165.1165.1 120.6127.0127.0 48.348.348.3 575757 92.192.192.13+0.53+0.56.3517.420.631.75 488 M18 M18 M18
 DN 3″(ANSI B 16.5 RF) 150psi 300psi 600psi 190.5209.5209.5 152.4168.3168.3 767676 757575 1271271273+0.53+0.56.3522.227.038.05 488 M16 M20 M20
DN 4″150psi22919189891573+0.5308M18
(ANSI B 16.5 RF)300psi25520089891573+0.5328M18

Note: The user can choose the mounting bolts and nuts.

Electrical connection diagram

Description of the process connection of the low-pressure end

Entre em contato conosco!

Ative o JavaScript no seu navegador para preencher este formulário.

parceiro

parceiro
Deixe um recado!
Fique à vontade para nos deixar uma mensagem e obter orçamentos de produtos. Responderemos em até 24 horas.
Ative o JavaScript no seu navegador para preencher este formulário.
POR FAVOR CONTATE-NOS
Ative o JavaScript no seu navegador para preencher este formulário.